File | Description | Size | Format | |
---|---|---|---|---|
3.7 MB | Adobe PDF | Request a copy |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
You are accessing a machine-readable page. In order to be human-readable, please install an RSS reader.
All articles published by MDPI are made immediately available worldwide under an open access license. No special permission is required to reuse all or part of the article published by MDPI, including figures and tables. For articles published under an open access Creative Common CC BY license, any part of the article may be reused without permission provided that the original article is clearly cited. For more information, please refer to https://www.mdpi.com/openaccess .
Feature papers represent the most advanced research with significant potential for high impact in the field. A Feature Paper should be a substantial original Article that involves several techniques or approaches, provides an outlook for future research directions and describes possible research applications.
Feature papers are submitted upon individual invitation or recommendation by the scientific editors and must receive positive feedback from the reviewers.
Editor’s Choice articles are based on recommendations by the scientific editors of MDPI journals from around the world. Editors select a small number of articles recently published in the journal that they believe will be particularly interesting to readers, or important in the respective research area. The aim is to provide a snapshot of some of the most exciting work published in the various research areas of the journal.
Original Submission Date Received: .
Find support for a specific problem in the support section of our website.
Please let us know what you think of our products and services.
Visit our dedicated information section to learn more about MDPI.
Mimo antennas: design approaches, techniques and applications.
2. mimo antenna design approaches, 2.1. envelope correlation coefficient (ecc), 2.2. diversity gain (dg), 2.3. channel capacity loss (ccl), 2.4. mean effective gain (meg), 2.5. total active reflection coefficient (tarc), 3. ultra-wideband (uwb) mimo antenna designs, 4. dual-band mimo antenna designs, 5. circularly polarized mimo antenna design approaches, 6. mimo antennas in indoor environment, 7. mimo characteristics for 6g technology, 8. conclusions, author contributions, institutional review board statement, informed consent statement, data availability statement, conflicts of interest.
Click here to enlarge figure
Ref. | MIMO Element | Antenna Size (mm ) | Antenna Frequency Band (GHz) | Bandwidth Improvement Technique | Isolation (dB) with Decoupling Techniques | Gain (dBi) | Efficiency (%) | ECC | CCL (bits/s/Hz) |
---|---|---|---|---|---|---|---|---|---|
[ ] | 4 × 4 | 48 × 34 × 1.6 | 3.52–10.08 | Modified rectangular patch | ≤−23 Neutralization line | 0.95–2.91 | 70.01–79.87 | ≤0.039 | ≤0.29 |
[ ] | 2 × 2 | 25 × 36 × 1.6 | 2.78–17.43 | Corner-truncated rhombus-shaped (CTRS) | <−19 Rectangular strip connected with GP | - | - | <0.008 | <0.31 |
[ ] | 2 × 2 | 36 × 22 × 1.6 | 2.5–2.85/4.82–6.1 | Square radiating patch | <−18 Flag-shaped stub connected with middle GP | 9.992 | - | <0.05 | - |
[ ] | 2 × 2 | 21 × 34 × 1.6 | 3.52–9.89 | Dome-shaped patch | ≤−22 Neutralization line | 3.08–5.12 | >62 | ≤0.005 | <0.26 |
[ ] | 2 × 2 | 30 × 50 × 1 | 3–10.9 | F-shaped radiators with L-shaped open-slots | ≤−20 Fork-shaped slots | 1.9–38 | - | <0.06 | - |
[ ] | 2 × 2 | 22 × 43.5 × 1 | 2.45 | L-shaped radiating patch | <−40 Tapered slot | 1.9 | 81.7 | 0.06 | - |
[ ] | 4 × 4 | 42 × 42 × 1 | 3.3–4.2 | Four conjoined slots | <−10 Circular slot | - | 47–64 | <0.06 | - |
[ ] | 4 × 4 | 45 × 45 × 1.6 | 4.3–6.45 | Split-shaped radiating patch | <−20 Decoupling structure | 4.0–5.0 | 90 | <0.2 | <0.018 |
[ ] | 4 × 4 | 40 × 40 × 1.6 | 3.1–11 | Circular patch | <−20 Decoupling structure | 3.28 (avg. gain) | - | <0.004 | <0.4 |
[ ] | 3 × 3 | 45 × 25 × 1.588 | 3.1–11.5 | Staircase-shaped radiators | ≤−19 Spatial diversity | 5.5 (peak gain) | 61–98 | ≤ 0.2 | - |
[ ] | 4 × 4 | 110 × 110 × 1.45 | 1.7–7.2 | Kraus technique | <−20 Electro-magnetic walls | 3.0–5.2 | 90 | 0.0025 | - |
[ ] | 2 × 2 | 29.5 × 60 × 1.6 | 3.05–20 | L-like stubs | <−20 Metallic barriers | 3.36–4.92 | 83 | <0.00012 | 0.325 |
[ ] | 2 × 2 | 50 × 35 × 1 | 3.0–11 | L-shaped parasitic branches | <−25 Fence-type decoupling structure | above 3 dB | >80 | <0.004 | - |
[ ] | 2 × 2 | 18 × 28 × 1.6 | 1.9–14 | Three crossed X-shaped stubs | <−15.5 X-shaped stubs in ground planes | 0.4–4.8 | - | <0.09 | <0.4 |
[ ] | 2 × 2 | 16 × 26 × 1.6 | 2.82–14.45 | Circular radiator | <−22 Stubs and protruded strip | 0.7–6.86 | ≥91.7 | <0.08 | - |
Ref. No. | MIMO Element | Antenna Size (mm ) | Antenna Frequency Band (GHz) | Technique to Achieve Dual-band | Isolation (dB) with Decoupling TECHNIQUES | Gain (dBi) | Efficiency (%) | ECC | CCL (bits/s/Hz) |
---|---|---|---|---|---|---|---|---|---|
[ ] | 2 × 2 | 20 × 34 × 16 | 2.11–4.19/4.98–6.81 | Embedding a pair of comb-shaped slots in the GP | <−21 T-stub with comb-shaped slots | 2.75–4.19 | >70 | <0.004 | <0.32 |
[ ] | 2 × 2 | 46 × 30 × 1.6 | 1.85–3.63/5.07–7.96 | Swastika-shaped slot in the rectangular patch | <−17.21 T-shaped narrow conducting strip in GP | 1.14–4.12/1.42–4.78 | 71.21–92.69/70.55–90.99 | <0.003 | <0.35 |
[ ] | 2 × 2 | 62 × 25.6 × 1.524 | 2.99–3.61/4.53–4.92 | Arrow-shaped strip in between the U-shaped patch | <−16 Defected ground with L-shaped slot with strip | 2.96–3.14/3.69–3.84 | 72.68–80.24 | <0.002 | <0.32 |
[ ] | 2 × 2 | 69 × 34 × 4.2 | 2.375–2.52/4.98–5.88 | Inverted F-shaped | <−18 Slots on GP | 2.66/5.18 | - | <0.01 | - |
[ ] | 2 × 2 | 52 × 77.5 × 1.6 | 2.4–2.48/5.15–5.825 | Horizontal U-strip | <−15 Inverted T-slot and meander line resonancebranch | - | - | <0.2 | - |
[ ] | 2 × 2 | 32 × 32 × 1.59 | 2.36–2.59/3.17–3.77 | T-shaped strip and rectangular strip | <−15 Rectangular microstrip stub with defected GP | 5.8 (peak gain) | 76 | <0.02 | - |
[ ] | 2 × 2 | 30 × 30 × 1.6 | 3.32–3.74/5.45–6.05 | Trapezoidal-shaped patch | <−20 T-shaped branch | <1.5/3.5 (peak gain both band) | - | - | - |
[ ] | 4 × 4 | 30 × 30 × 0.8 | 4.58–6.12 | Rectangular patch | <−15.4 Swastika- shaped decoupling strip | 4.02 | 67–82 | <0.15 | - |
[ ] | 4 × 4 | 40 × 40 × 1.6 | 2.93/5.68 | L-shaped with split ring resonator | <−14 SRR | 4 | 83.48–89.55 | <0.05 | <0.5 |
[ ] | 4 × 4 | 85 × 85 × 0.8 | 2.32–2.95 | Metal strip | <−14 Parasitic element | 5.5 | 83 −90 | <0.008 | - |
[ ] | 4 × 4 | 38 × 38 × 1.6 | 2.38–2.45/2.96–4.01 | Two asymmetric U-shaped slots in the radiating patch | ≤−18 Four metallic strips in the GP | - | - | <0.008 | <0.35 |
[ ] | 2 × 2 | 70 × 70 × 0.8 | 2.4~2.5/5.6~5.8 | Width of branches | <−25 Loadeddummy elements | - | Not given value | Not given value | - |
[ ] | 2 × 2 | 72 × 56 × 0.8 | 2.24–2.90/3.9–7.55 | Rectangle split-ring-resonator | <−24 ITI-shaped structure | 2.5–5.6 | - | <0.04 | <0.4 |
[ ] | 2 × 2 | 105 × 105 × 1.83 | 2.23–2.46/3.22–4.04 | Slotted interconnected ring resonator | <−12 | 3.6/7.1 (peak gain) | 74–84 | 0.002 | - |
[ ] | 1 × 2 | 51 × 29.6 × 1.6 | 2.4/5.2 | Slotted rectangular patch | <−25 EBG structure | 2.2/3.8 (peak gain) | - | 0.07 | - |
[ ] | 4 × 4 | 58 × 60 × 1.6 | 1.55–2.65/3.35–3.65 | Two opposite slots in the radiating elements | <−10 Orthogonal plus-shaped partial ground | 2.2/3.8 | - | <0.08 | <0.4 |
[ ] | 2 × 2 | 38.6 × 56.4 × 1.524 | 3.5/4.85 | L-shaped branches | <−29 DGS and ground branches | 2.45/4.56 | - | <0.005 | - |
Ref. | MIMO Element | Antenna Size (mm ) | Frequency Band (GHz) | 3-dB AR Bandwidth (GHz) | CP Technique | Gain (dBi) | Isolation (dB) | ECC | CCL bits/s/Hz |
---|---|---|---|---|---|---|---|---|---|
[ ] | 2 × 2 | 24 × 24 × 1.6 | 3.04–8.11 | 4.42–6.11 | Asymmetric Z-shaped patch with stub loaded defected GP | 0.28–2.76 | <−16 | <0.004 | <0.32 |
[ ] | 2 × 2 | 56 × 32 × 3 | 5.10–5.85 | 5.10–5.85 | Truncated corner patch with defected periodic GP | 5.8 | ≤−20 | - | - |
[ ] | 2 × 2 | 95 × 49.7 × 1.6 | 3.15–3.93 | 3.3–3.8 | Cross ring slot with DRA truncation | 4.83 | <−26 | < 0.03 | <0.10 |
[ ] | 2 × 2 | 50 × 70 × 1.6 | 2.21–3.13/3.40–3.92/5.30–6.10 | 5.62–5.86 | Dual strips along with single slot in the GP | 4.1 | <−28 | <0.15 | <0.23 |
[ ] | 2 × 2 | 40 × 65 × 1.6 | 5.16–6.30 | 5.20–5.58 | L-shaped DRA | 4.011 | 22.284 | <0.112 | <0.338 |
[ ] | 2 × 2 | 350 × 350 × 26.1 | 3.50–4.95 | 3.58–4.40 | Rectangular DRA with parasitic patch | 6.2 | <−28 | <0.04 | - |
[ ] | 2 × 2 | 22.5 × 50 × 1.6 | 5.2–6.4 | 5.37–5.72 | Square slot cut in the corner of the GP | 6 (Peak gain) | <−20 | 0.001 | - |
[ ] | 4 × 4 | 70 × 68 × 1.6 | 4–13 | 4.2–8.5 | Cross-shaped structure on ground | 6.4 (Peak gain) | ≤−18 | <0.25 | - |
[ ] | 2 × 2 | 150 × 100 × 0.8 | 2.47–2.55 | 2.50–2.66 | Offset feeding | 6.1 (Peak gain) | ≤−20 | 0.003 | - |
[ ] | 4 × 4 | 80 × 80 × 11.6 | 3.35–3.82/5.09–5.41 | 3.54–3.72/5.04–5.16 | Z-shaped slots | 5.0–6.8 | <−18 | <0.04 | - |
[ ] | 2 × 2 | 80 × 40 × 1.6 | 2.9–3.2/3.44–3.64/4.75–5.5 | 3.32–3.58/ 5.0–5.32 | Z-shaped slots in the GP | 2 | ≤−15 | <0.2 | - |
[ ] | 2 × 2 | - | 4.75–5.9 | 5.1–5.8 | Parasitic elements | 7.5–8.2 | ≤−22 | - | - |
MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
Sharma, P.; Tiwari, R.N.; Singh, P.; Kumar, P.; Kanaujia, B.K. MIMO Antennas: Design Approaches, Techniques and Applications. Sensors 2022 , 22 , 7813. https://doi.org/10.3390/s22207813
Sharma P, Tiwari RN, Singh P, Kumar P, Kanaujia BK. MIMO Antennas: Design Approaches, Techniques and Applications. Sensors . 2022; 22(20):7813. https://doi.org/10.3390/s22207813
Sharma, Preeti, Rakesh N. Tiwari, Prabhakar Singh, Pradeep Kumar, and Binod K. Kanaujia. 2022. "MIMO Antennas: Design Approaches, Techniques and Applications" Sensors 22, no. 20: 7813. https://doi.org/10.3390/s22207813
Article access statistics, further information, mdpi initiatives, follow mdpi.
Subscribe to receive issue release notifications and newsletters from MDPI journals
Show full item record
A not-for-profit organization, IEEE is the world's largest technical professional organization dedicated to advancing technology for the benefit of humanity. © Copyright 2024 IEEE - All rights reserved. Use of this web site signifies your agreement to the terms and conditions.
An official website of the United States government
The .gov means it’s official. Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.
The site is secure. The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.
Preview improvements coming to the PMC website in October 2024. Learn More or Try it out now .
Khaled aliqab.
1 Department of Electrical Engineering, College of Engineering, Jouf University, Sakaka 72388, Saudi Arabia
2 Department of Information Engineering and Mathematics Science, University of Siena, 53100 Siena, Italy; [email protected]
3 Institute of Sensors, Signals and Systems, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, UK
No new data were created in this research.
In-body biomedical devices (IBBDs) are receiving significant attention in the discovery of solutions to complex medical conditions. Biomedical devices, which can be ingested, injected or implanted in the human body, have made it viable to screen the physiological signs of a patient wirelessly, without regular hospital appointments and routine check-ups, where the antenna is a mandatory element for transferring bio-data from the IBBDs to the external world. However, the design of an in-body antenna is challenging due to the dispersion of the dielectric constant of the tissues and unpredictability of the organ structures of the human body, which can absorb most of the antenna radiation. Therefore, various factors must be considered for an in-body antenna, such as miniaturization, link budget, patient safety, biocompatibility, low power consumption and the ability to work effectively within acceptable medical frequency bands. This paper presents a comprehensive overview of the major facets associated with the design and challenges of in-body antennas. The review comprises surveying the design specifications and implementation methodology, simulation software and testing of in-body biomedical antennas. This work aims to summarize the recent in-body antenna innovations for biomedical applications and indicates the key research challenges.
Body-centric communication system (BWCS) is an emerging technology referring to human self and human-to-human networking, which uses implantable and wearable sensors [ 1 ]. BWCS is a combined field of wireless body area networks (WBANs), wireless personal area networks (WPANs) and wireless sensor networks (WSNs). It is also classified as off-body, on-body and in-body communication, as shown in Figure 1 . On-body communication is the communication between different wearable devices. The communication between an outside and an on-body device is designated as off-body communication [ 2 ]. In-body communication system means the communication of implantable devices and sensors inside the body with an external device or communication with another implant. In-body biomedical devices (IBBDs) are designed to monitor physiological data inside the human body and provide key support to improve the quality of life through disease prevention, therapy and diagnosis, such as drug delivery system, neurostimulators, bone growth stimulators, and treatment of numerous severe conditions in the medical profession [ 3 ]. Wireless IBBDs are divided into implantables, ingestibles and injectables based on the way they are inserted into the human body [ 4 ]. Specifically, implantable devices are the most common type of IBBDs sited inside the human body through a surgical operation [ 5 ]. In the last decade, implants have advanced from bulky pacemakers to micro-sized deep brain implants [ 6 ]. Ingestible devices are generally capsule-shaped devices, which are ingested and swallowed, similar to regular pills [ 7 ]. The most conventional ingestible device is the wireless endoscopic capsule, which was originally discovered in the year 2000 [ 8 ]. Currently, wireless ingestible capsules are equipped with cutting-edge abilities, which can also monitor the side effects of pharmaceuticals [ 9 ].
Types of BWCS.
Lastly, injectable devices [ 10 ] are micro-sized devices, which can be injected into the human body using needles. Recently, these devices have been commonly used for important sensing and neurostimulation applications [ 10 ]. The primary components of an IBBD are the antenna, battery, the processing system and sensors [ 11 ]. The reliability and strength of the wireless link between the external and internal device largely depend on the antenna mounted on an IBBD. Therefore, the antenna is a key construction block of an IBBD, as the primary working requirement of signal reception and transmission depends mainly on the performance of the antenna. Furthermore, the overall size and weight of the IBBD can also be affected by it.
In IBBDs, the antenna is primarily used for wireless communication and data transfer [ 12 , 13 ], wireless power transfer (WPT) [ 14 ] and sensing [ 15 , 16 ], which lead to a wide range of medical applications, including continuous pressure measurements, dental antenna for remote healthcare, intracranial pressure monitoring, glucose level check, insulin pump, radiometer/heating therapy, pacemaker connection, endoscopic capsule and blood pressure measurements [ 17 ].
The design of an in-body antenna is challenging, as it is mostly situated in electromagnetically harsh and lossy environments inside the human body. The electromagnetic (EM) wave passing through the lossy heterogeneous tissue inside the human body can cause significant absorption of most of the antenna radiations [ 18 ]. Such inhomogeneous human organ structure is the primary reason for the impedance mismatch, which makes the radiation performance inefficient. This also affects the antenna efficiency significantly [ 19 ]. The powering of an in-body antenna attached to an IBBD inside the human body is another key research challenge. The commonly used batteries in IBBDs are bulky in size with limited capacity and can complicate the system design process [ 20 ]. Recently, in-body antennas for WPT have become a great research interest [ 14 ]. WPT necessitates an appropriate selection of the frequency band, which is a vital component of the in-body antenna system for biomedical applications. The operation frequency band of an in-body antenna must avoid EM interference with the current terrestrial frequency bands [ 21 ]. Furthermore, the fabrication and testing of such miniaturized in-body antennas inside the human body are extremely challenging due to the inadequately accredited animal laboratories, along with major health and safety related issues [ 22 , 23 ].
The growing research in this area demands a comprehensive overview in order to acquaint the new researchers and antenna designers with the state of the art and current developments. This review work aims to describe the design specifications, implementation and testing techniques, challenges and different applications of in-body antennas. Following the Introduction, the paper is divided into six sections. Section 2 briefly highlights the design specifications of in-body antennas. Section 3 explains the in-body antenna design, manufacturing and testing process. Section 4 outlines the different challenges in the development of in-body antennas. Section 5 details the different antenna types being used in different IBBD applications and compares their performances critically. Section 6 briefly discusses the limitations of the current in-body antenna designs and indicates future research scopes. Finally, the conclusions are drawn in Section 7 .
2.1. operation frequency bands.
Figure 2 shows different frequency bands allocated for in-body antennas. The choice of an operation frequency for IBBDs involves several trade-offs. Generally, lower frequencies are attractive and commonly used, as they facilitate lower loss of the biological tissue medium, which can lead to higher efficiency and better tissue safety. However, lower frequencies have the drawback of limiting the communication speed and requiring larger antenna size. In contrast, higher frequency bands provide high data rates and miniaturization at the cost of lower tissue safety. In Figure 2 , frequencies below 100 kHz are allocated for short-range inductive IBBDs by the Federal Communication Commission (FCC) in the United States (US) for lower power and data transmission [ 21 ]. Medical micropower networks (MMNs) are another FCC-approved short-range frequency band with a 24 MHz spectrum from 413 to 457 MHz. Furthermore, Wi-Fi (902–928 MHz), Bluetooth (2.40–2.483 GHz) and Zigbee (5.725–5.850 GHz) are designated for short-range digital modulation communication for IBBDs by the FCC in the US.
Frequency bands for in-body antennas.
In Europe, the Electronic Communication Committee (ECC) allocated the 430 to 440 MHz band for ultra-low-power wireless medical capsule endoscopy (ULP-WMCE) and the 2.483 to 2.50 GHz band for active medical implants (AMI). The Medical Device Radio Communication Service (MedRadio) band of 401–406 MHz [ 4 ], Medical Implant Communication System (MICS) band of 402–405 MHz [ 24 ] and Industrial, Scientific and Medical (ISM) band of 13.56 MHz, 433–434 MHz, 902–908 MHz, 2.40–2.48 GHz and 5.717–5.875 GHz [ 25 ] are accepted worldwide for IBBD application.
Antenna miniaturization is a key specification for IBBDs. In MedRadio, MICS and common ISM bands, the effective size of the in-body antenna at the desired resonance frequency becomes significantly larger. This can create difficulties during the implantation process of IBBDs in human tissue [ 2 ]. Therefore, the size of in-body antennas is considered very crucial, and miniaturization techniques, such as changing the physical properties of the structure, varying the material characteristics or introducing supplementary elements, are used to solve these kinds of challenges.
High permittivity substrate/superstrate material can shift the antenna resonant frequency near to the lower frequency band, which shortens the operation wavelength [ 2 ]. This simple technique can provide a higher degree of miniaturization. Some of the materials, which are generally used as a dielectric substrate for in-body antennas, include alumina ceramic (relative permittivity, ε r = 9.4) [ 26 , 27 ] and Rogers 3210 [ 28 ], 3010 [ 29 ], 6002 [ 30 ] with ε r = 10.2. A substantial reduction in effective antenna length is realized by using MgTa 1.5 Nb 0.5 O 6 as a dielectric substrate, with the dielectric constant ε r = 28 [ 31 ]. However, this method results in a significant level of surface wave excitation within the substrate. This results in lower bandwidth and a decrease in overall radiation efficiency [ 32 ]. The higher cost of these materials is another issue.
By modifying the physical properties of an in-body antenna, it is possible to attain a prolonged path of effective current flow. This shifts the resonant frequency to a lower band, resulting in significant size reduction of the antenna [ 2 , 17 ]. Numerous design techniques are considered for this purpose, such as meandered [ 33 ], spiral [ 33 ], hook slotted [ 3 ], waffle type [ 30 ] and radiator staking methods [ 27 ]. This technique can suffer from higher ohmic loss, resulting in lower radiation efficiency [ 32 ].
In-body antennas commonly require the matching of impedance at the anticipated frequency of operation using loading techniques. The loading can possibly be inductive or capacitive, which can effectively minimize the imaginary part of the impedance by nullifying the effect of reactance, helping in size reduction. In Ref. [ 29 ], a circularly polarized implantable patch antenna was presented, where the size was reduced due to the use of capacitive loading compared to traditional square patch antenna. However, the impedance matching of a high-quality-factor ( Q -factor) in-body antenna can lead to performance issues and may require a separate compensation network. This can also reduce the bandwidth of the antenna.
Introducing a shorting pin between the patch planes and the ground increases the effective size of the antenna, resulting in a reduction of the essential physical dimensions of it for an explicit frequency of operation [ 2 , 3 ]. This is a similar technique, where the ground plane doubles the height of a monopole antenna. Therefore, it generally produces a planar inverted-F antenna (PIFA) with identical resonance performance, similar to a double-sized antenna deprived of the shorting pin [ 34 ]. However, it can cause a reduction in antenna aperture, resulting in a significant decrease in antenna directivity, which can affect the effective gain of the antenna directly [ 32 ].
The use of a higher frequency band can reduce the size of the in-body antenna significantly. Higher frequencies of operation have shorter wavelengths, which leads to a decrease in antenna size [ 2 , 17 ]. Alternatively, if the antenna size is reduced, the resonant frequency of the antenna will move to a higher band and vice versa. Higher frequencies with a wide bandwidth are also desirable for better data communication [ 35 ]. However, they suffer from higher tissue attenuation and loss compared to lower frequencies, which affect the overall in-body antenna performance by inducing more losses [ 36 ]. It is also necessary to maintain the operation frequency band specification, as described in Section 2.1 .
In-body antennas can also be miniaturized by modifying their ground plane. Generally, the model of an in-body antenna considers infinite ground plane. In practice, the ground plane is designed as finite. For large-scale miniaturization, the size of the ground plane is further reduced in a way where, at times, it is slightly larger than the dimensions of the patch [ 32 ]. Refs. [ 37 , 38 , 39 ] present an analysis of truncated ground planes. Such miniaturization can be achieved by introducing a slot in the ground plane, which can alter the return path of the current to slow down the current flow. This causes a phase shift of the displacement of the current from one edge of the slot to the other, resulting in a smaller antenna size [ 40 ]. However, such in-body antenna has a reduced polarization concentration, and reducing the size of the ground plane can also affect input impedance. Furthermore, the edge diffraction due to ground plane modification can generate significant back lobe radiation, resulting in a reduction in front-to-back ratio [ 32 ].
Metamaterials are defined as artificially engineered materials, which are designed to provide material properties that are not commercially available to satisfy any extraordinary conditions [ 41 ]. They can also be engineered to achieve materials with close-to-zero values of permittivity, negative permittivity or permeability, or simultaneous negative permittivity and permeability. Therefore, they can dramatically reduce the in-body antenna size and can also improve its bandwidth and gain [ 42 ]. In Ref. [ 43 ], a circularly polarized in-body antenna could achieve 84% size reduction by using a metamaterial design. Although the use of metamaterials has been effective in reducing antenna size, there is a substantial cost in terms of using a complex material, significantly narrow operating bandwidths and lower radiation efficiencies [ 32 ]. Additionally, in metamaterial-based miniaturization methods, substantial care must be taken with the analytical models, which are used for the analysis. These analytical models typically ignore the polarization of the field, which might cause different behaviors as compared with the regular incidence or non-polarized models commonly used for analysis to calculate the effective medium properties.
Figure 3 shows a generalized wireless communication link between an external device and an IBBD with a transceiver system and an antenna on each side.
Wireless communication link between external device and IBBD.
The wireless communication link can be classified as near field and far field. The near field technique includes inductive coupling [ 14 ]. It was the technology integrated into the first wireless implants at an operation frequency of 20 MHz or lower [ 4 ]. This technology established the use of inductors within IBBDs and external devices, which were located in close proximity to initiate wireless communication through coupling. The link design strategies for inductively coupled IBBDs are explained broadly in Refs. [ 14 , 44 ]. In far field, the link power budget can be written as [ 29 ]
where C / N 0 is the ratio of the carrier power and noise density; P t , G t , L f , G r , B r , G c , G d and E b / N 0 are the transmit power, transmit antenna gain, path loss (free space), receiver antenna gain, receiver bit rate, receiver coding gain, receiver deterioration and the ratio of energy per bit and noise density, respectively. The path loss can be calculated according to the free-space reduction in signal strength with the distance d between the transmitter and receiver as [ 29 ]
Furthermore, the impedance mismatch loss can be calculated as
where Γ is the appropriate reflection coefficient. The loss in human body is not considered in Equation (1), and this will be explained further in Section 4 , where different challenges for in-body antenna design are described.
IBBDs have been conventionally powered via batteries [ 11 , 45 ]. However, integration of the batteries can upsurge the size of the IBBDs, raising biocompatibility and patient safety related concerns. This also necessitates the requirement for frequent battery replacement and/or recharging due to short lifetime. Therefore, the research on battery-less techniques, such as energy harvesting and WPT, for IBBDs is becoming necessary. Energy harvesting technologies involve harvesting the power from environmental or human bodily sources. The motion of the tissue and heartbeat [ 46 ], body thermal gradients [ 47 ], human movement and motion [ 48 ], and glucose oxidization [ 49 ] are some of the mechanisms used in the past to harvest the energy for IBBDs. Different WPT techniques and their design methodologies for IBBDs are explained in Ref. [ 14 ]. Widespread research has been carried out in the last decade to improve the efficiencies of the aforementioned approaches and develop them to be used for powering IBBDs.
In-body antennas are installed in human bodies, so they must have biocompatible properties in order to satisfy patient safety. If in-body antennas are directly embedded into the human body, the body is short circuited due to the fact that human tissues are conductors. Therefore, as a measure to prevent such undesirable short circuit cases, biocompatibility becomes necessary for extended-term implantation of in-body antennas. Two types of methods are mostly proposed for biocompatibility issues of implantable antennas [ 3 ]. The first approach is to use a biocompatible substrate for antenna manufacturing, and the second approach is to cover the implantable antenna with a thin coating layer of biocompatible low-loss material. The biocompatible superstrate materials proposed for in-body antennas are Teflon, MACOR and Ceramic Alumina [ 34 ]. However, it is problematic to drill and assemble round cuts in ceramic substrates [ 50 , 51 ]. The materials proposed for antenna coating are PEEK [ 52 ], Zirconia [ 53 ], biomedical-grade-based Silastic MDX-4210 elastomer [ 51 ]. A significantly slim layer of low-loss biocompatible material coating increases the properties of biocompatibility in in-body antennas. However, a cautious design of the in-body antenna is required to avoid any performance dependencies related to the thickness of the biocompatible layer [ 54 ]. An improvement in the biocompatibility of in-body antenna coating Perylene C material on both sides of the antenna is also proposed in Ref. [ 55 ]. The electromagnetic properties of Zirconia make it a better contender for bio-encapsulation [ 3 ]. Its significantly lower loss tangent and higher permittivity value help decrease the power loss by accumulating the near field of the antenna inside the capsulation. Additionally, the benefit of PEEK and Silastic MDX-4210 is that they offer simple fabrication processes and are easy to handle.
The maximum allowable power incident in the in-body antenna is limited by issues related to patient safety. The specific absorption rate (SAR), which represents the amount of energy deposited per unit mass of tissue, is usually accepted as the most suitable scientific measure in compliance with international guidelines. The IEEE C95.1-1999 standard confines the average SAR over any 1 g of tissue in the shape of a cube to less than 1.6 W/kg (SAR 1g, max ≤ 1.6 W/kg) [ 56 ], which is followed by the FCC in the US. The international commission on non-ionizing radiation protection (ICNIRP) standardizes the limit of SAR averaged over 10 g of contiguous tissue to be less than 2 W/kg [ 57 ]. To comply with ICNIRP guidelines, the IEEE C95.1-2005 standard limits the average SAR over any 10 g of tissue in the shape of a cube to less than 2 W/kg (SAR 10g, max ≤ 2 W/kg), which is followed by the European Union [ 58 ].
Figure 4 shows the generalized steps for designing, manufacturing and testing in-body antennas. In the first step, the researchers benchmark the antenna parameters based on the specifications provided in Section 2 . These parameters are then used to generate an analytical model, which leads to analysis and simulation in programming and numeric computing platforms, such as MATLAB [ 44 , 59 , 60 , 61 , 62 , 63 , 64 ]. This is an important step of optimizing the antenna to accomplish the best performance [ 65 ].
Generalized steps for designing, manufacturing and testing in-body antennas.
In the next step, the data generated from the analytical model are used to build a 3D antenna simulation environment using electromagnetic (EM) software, such as Ansys high frequency structure simulator (HFSS) [ 66 ] https://www.ansys.com/en-gb/products/electronics/ansys-hfss (accessed 15 May 2023), Dassault Systems CST microwave suite [ 67 ] https://www.3ds.com/products-services/simulia/products/cst-studio-suite/ (accessed 15 May 2023), finite difference time domain (FDTD) [ 68 ] https://optics.ansys.com/hc/en-us/articles/360034914633-Finite-Difference-Time-Domain-FDTD-solver-introduction (accessed 15 May 2023), Altair FEKO [ 69 ] https://altair.com/feko (accessed 16 May 2023) and COMSOL [ 64 ] https://www.comsol.com/rf-module (accessed 16 May 2023). Furthermore, Ansys Maxwell 3D [ 70 ] and Dassault Systems Simulia are low frequency solvers used to design in-body antennas with lower MHz to kHz frequency ranges. The analytical model and EM software simulation results are compared to verify and confirm the antenna parameters before manufacturing in-body antennas.
Detailed methodology of the manufacturing process of an in-body patch-type planar antenna has been outlined in Ref. [ 65 ]. In antenna manufacturing, a photolithography mask is first produced to confirm the antenna geometry, including antenna layers, which are going to be stacked on the plane. In the next step, the antenna layers are etched according to the antenna geometry using the photolithography mask. Furthermore, the lower substrate comprises the ground and lower patch; the upper substrate comprises the upper patch; and the superstrate is positioned on the top. Additionally, a circular-shaped hole is etched as per the patch geometry, where four pins are located at the base of the mask. Afterward, all the layers are machined to the circular format, and the layers of the antenna are positioned in a straight line.
This process must be conducted without putting much more mechanical stress on the antenna. Finally, the layers of the antenna are organized in a mountain format and glued to attach all the layers in case of a multi-layered structure. This step is not required for single-layer microstrip patch planar antenna. In the next step, the shorting pin is attached to the ground plane and lower patch. Therefore, the outer conductor of the co-axial feeding point is connected to the ground. Furthermore, the inner conductor is soldered to the lower and upper patch. This methodology is commonly used in research laboratories to validate the antenna parameters with respect to simulation. However, low-temperature ceramic Co-fire (LTCC) is a popular method used in industrial manufacturing. Helical antennas built with conductive wires are generally wound by hand and coil-winder-machined with a counter for laboratory testing and industrial manufacturing, respectively. The manufactured antenna is first characterized in the air, and the measured results are compared with the EM software simulation outputs. In case of a major discrepancy, the researchers go back to the previous step and reiterate it, as shown in Figure 4 . Otherwise, the in-body antenna is tested inside phantom (in vitro) and animal tissue (in vivo) successively.
The manufactured in-body antenna is verified in the in vitro antenna testing procedure using an artificially built biological environment or phantom [ 65 ]. The biological tissue properties (relative permittivity and electrical conductance) of different parts of the body at different operating frequencies are provided in the Foundation for Research on Information Technologies in Society (IT’IS) website, which was established through the resourcefulness and support of the Swiss Federal Institute of Technology (ETH) in Zurich [ 71 ]. Before preparing the phantom of a particular body part, it is necessary to know its permittivity and electrical conductance at the in-body antenna operation frequency. Low-frequency band liquid phantom, as shown in Figure 5 , is investigated in Refs. [ 70 , 72 ], where purified water, polyethylene powder and NaCl are used as the main material, relative permittivity and conductivity generation material, respectively. Several works presented the investigation of the phantom in the ISM and MICS bands [ 13 , 28 , 73 , 74 ]. In Ref. [ 13 ], a gel type phantom imitating the properties of muscle tissue is built with hydrophilic organic powder and degassed water, as shown in Figure 6 .
Liquid phantom for capsule localization investigation [ 70 ]. Reproduced with permission from an open-access article from IEEE Access (CC-BY).
( a ) Phantom setup. ( b ) Indentation of capsule in phantom [ 13 ]. Reproduced with permission from an open-access article from IEEE (CC-BY).
A traditional method of measuring the tissue properties of a phantom is the co-axial probe, where a dielectric probe kit, such as SPEAG DAK 3.5, along with a vector network analyzer, such as Agilent 8753ES, are used [ 75 ]. An alternative method utilized in the literature involves a dielectric resonator in close contact with the tissue [ 76 ]. These measurement techniques utilize the input reflection coefficient to calculate the material dielectric properties. Measurement uncertainty is significant for higher permittivity values, as there is less change in the measured reflection coefficient for discrepancies in material permittivity [ 75 ].
In vitro study is commonly carried out in an artificial biological environment, which cannot confirm the stability of the implanted antenna system because of the lack of dynamic illustration of a real biological environment in the in vitro study [ 51 ]. Therefore, the testing of in-body antenna in a real biological environment (in vivo) is commonly suggested after in vitro testing. Before implantation of the in-body antenna prototype inside the biological body, it is necessary to ensure that the temperature of the testing environment is below 100 °C. Generally, the in-body antenna itself generates heat up to 60 °C because of the battery and other internal system devices. Furthermore, the in-body antenna must be insulated by using biocompatible material to protect the antenna system from coupling loss, as described in Section 2.5 . Figure 7 and Figure 8 [ 23 , 77 ] illustrate the in vivo testing of the glucose monitoring implantable antenna in a rat and monitoring of blood pressure of the left ventricle, respectively.
Multi-layer implantable antenna measurement for continuous glucose monitoring. ( a ) A sensor implanted in a rat, ( b ) Experimental setup [ 77 ]. Reproduced by courtesy of the Electromagnetics Academy.
Anesthetized mixed landrace pig with ( a ) exposed left ventricular (LV) apex, ( b ) implanted wireless pressure sensor, ( c ) catheter-tip transducer and ( d ) chest spreader [ 23 ]. Reproduced with permission from an open-access article from Biomedical Microdevices (CC-BY).
The development of in-body antennas faces numerous design challenges. Miniaturizing the effective electrical size of an antenna leads to a reduction in its electromagnetic performance [ 78 ]. Furthermore, it is necessary to consider some important factors to ensure patient safety during the design phase of in-body antennas. First, the in-body antenna is required to be biocompatible, and the SAR must be controlled within the standard limit. This section describes the factors that influence the design specifications of in-body antennas.
The propagation of a radio wave through the biological tissue is more complex compared to wave propagation in a free space due to the lossy property of the biological tissue causing absorption. Absorption in a radio wave is primarily characterized by considering the permeability, permittivity and conductivity parameters of the medium. An EM wave propagating in the positive Z -direction is defined as [ 79 ]
where E and γ are the complex amplitude of the wave in the z -direction and the complex propagation constant, respectively. γ is defined as [ 79 , 80 ]
The constant increase in γ leads to attenuation of the electromagnetic wave inside the inhomogeneous region, where µ = µ r µ 0 = µ 0 defines the permeability of the medium, as for biological materials µ r = 1. However, the relative permittivity ε r (where ε = ε 0 ε r ) of human body tissue is a complex frequency-dependent parameter, as the conductivity σ is not zero. The dielectric properties of the human tissue can be obtained from its relative complex permittivity as [ 81 ]
where ε r ′ and ε r ″ are the real and imaginary parts of relative complex permittivity. The imaginary part of relative complex permittivity can be determined from the angular frequency ω and conductivity σ by
Furthermore, the loss tangent, tan δ , which is a measure of how lossy the human body can be, is calculated as follows:
Therefore, as per Equation (7), greater conductivity demonstrates a higher relative complex permittivity value. Furthermore, the increase in the frequency leads to a lower value of imaginary relative complex permittivity in a lossy medium. As a result, the increase in the loss tangent makes the medium significantly lossy. In brief, the complex propagation constant depends on three parameters: permittivity, permeability and conductivity. The increase in conductivity can cause lossy medium, where the radio waves can be significantly attenuated. Therefore, the EM wave attenuates with the increase in the complex propagation constant, as specified in Equation (4).
Another major issue with tissue diversification is that the radio wave propagation speed decreases because of the complex inhomogeneous characteristics of biological tissue. Therefore, the radio wave propagation speed primarily depends on the permittivity and conductivity of the medium. Additionally, the propagation speed in any medium is characterized based on phase ( V p ) and group ( V g ) velocity as [ 79 , 82 ]
where β is the phase constant, defined from the complex propagation constant as [ 83 ]
In Equations (9) and (10), the propagation speed is characterized based on the phase constant, and it decreases with the increase in the conductivity of the medium. In contrast, the rise in the frequency influences the increase in propagation speed. In summary, higher conductivity of biological tissues can cause significant reduction in the propagation speed of radio waves.
In Ref. [ 79 ], the effective wavelength λ in any medium is defined as
The phase constant β is dependent on conductivity σ proportionally. The rise in medium conductivity reduces λ, which therefore leads to miniaturization of the in-body antenna. In an ideal case, in order to facilitate a surgical procedure, the IBBDs have to be in the range of 1 to 10 mm in diameter for a length of 5 to 35 mm, while in the MedRadio and ISM bands, the free-space wavelength is approximately 74 and 12 cm, respectively [ 78 ]. This indicates that in-body antennas must be profoundly miniaturized, leading to antenna dimensions of some fractions of the free-space wavelength (typically λ /30 and λ /5 for the MedRadio and ISM bands, respectively).
In a free space, the radiated power of an antenna depends on the far field elements only, as the near field is mostly reactive and therefore not distressing the radiated or the absorbed power [ 78 ]. In the case of an antenna radiating into lossy matter, the near field component plays a key role by causing strong coupling with the surrounding medium near to the antenna and hence increases the losses. Therefore, the total radiated power primarily depends on the radial distance r . The outer boundaries of the near field and far field are commonly assumed as r < 0.62 D 3 / λ and r < D 2 / λ , where D is the antenna’s highest dimension [ 84 ]. In the case of in-body antennas, the situation improves slightly because the complex lossy medium surrounding the antenna is of finite dimensions. In the lossy medium, strong coupling with nearby lossy biological tissues is caused by the radiated radio wave. Therefore, the coupling of frequency causes a loss of radiated power. This coupling is also the primary driver of lower radiation efficiency of in-body antennas. Furthermore, biocompatibility encapsulation using insulating materials plays a key role in reducing the coupling with the adjacent lossy environment [ 78 ].
The process of covering the in-body antenna with biocompatible material is known as encapsulation. In Ref. [ 78 ], the effect of encapsulation on radiation efficiency is described through a comparative study between Zirconia and PEEK used as encapsulation shells for in-body antennas. It was observed that Zirconia demonstrates better results than PEEK due to its significantly lower loss and higher dielectric constant, which agrees with a higher concentration of the near field in the low-loss surrounding of the in-body antenna. Furthermore, a thicker encapsulation facilitates overall low losses. However, in the case of PEEK, this effect reaches saturation after a thickness of 2 mm, where the losses are approximately similar for a thickness of 3 mm. It was also noticed that PEEK is the kind of material, which can be handled and manufactured far more easily than Zirconia, thus being more suitable for IBBDs. In summary, low-loss encapsulation helps mitigate the loss by concentrating the near field in a low-loss region.
In-body antennas are compact in size and subject to narrower bandwidth [ 78 ]. However, all the radiated power from a transmitter does not reach the receiver because of significant absorption and reflection by the biological tissue medium. In an in-body antenna, the absorbed power is commonly greater than the reflected power, which generally causes the bandwidth to be wider. This also causes lower radiation efficiency of the antenna. It is possible to reduce these losses by using bio-encapsulation—as discussed in the previous section—and impedance matching, making the bandwidth narrower. However, an in-body antenna with narrow bandwidth suffers from frequency detuning inside the biological tissue environment. Therefore, a cautious consideration is necessary to solve this issue. The bandwidth of the in-body antenna can be improved by using a thicker substrate. In Ref. [ 85 ], the bandwidth of an implantable monopole antenna is improved by connecting a strip line with U-shaped ground. In Ref. [ 86 ], the ground plane of the implantable PIFA antenna is partly connected to a RFID circuit to enhance the bandwidth.
The lossy medium present in a human body environment can cause broadening of the radiation pattern because of the reflection, refraction and scattering existing in or generated from the body tissues [ 78 ]. The radiation pattern of an in-body antenna would also be variable in the same medium if the mounting circumstances and in-body positions were different.
As explained in Section 2.6 , SAR is used as a metric to guarantee the safety of biological tissues in the event of severe electromagnetic exposure. The standard SAR levels are maintained by IBBDs by considering low output power. In general, the specific absorption ( SA ) per pulse can be calculated by [ 87 ]
where T p represents the pulse duration. The EM power absorbed by the biological tissue medium can raise the temperature of the tissue. It must be noted that the temperature of the biological tissues adjacent to the implanted device should not rise more than 1–2 °C.
A remarkable level of EIRP of the in-body antenna can be harmful to the biological tissues, and it can create interference with the nearby radio devices. The standardized limit of EIRP for an in-body antenna functioning in the MedRadio band is −16 dBm [ 88 ] and −36 dBm at 915 MHz for the ISM band [ 89 ]. In case the in-body antenna is used for data telemetry, the input power must be limited to alleviate damage to the tissues. If the in-body antenna is operating as a receiver, the external source of power must follow the aforementioned standards.
Continuous power delivery to the IBBDs is one of the foremost challenges for in-body antennas. The current battery technologies are an inefficient solution for such application due to their short lifetime [ 11 , 14 ]. Furthermore, batteries contain hazardous ingredients and necessitate a surgical operation to be replaced. Additionally, the power system of IBBDs must be lightweight and easy to fabricate to facilitate an easy movement of patients. It is also necessary to maintain the energy level of the system in the design of a powering system for IBBDs.
This section explains the range of applications of IBBDs (implantable, ingestible and injectable devices) implemented with different types of in-body antennas.
A compact meander line planar implantable antenna for a pacemaker application operating at 402.5 MHz with a bandwidth of 33.5% is presented by Samsuri et al. in Ref. [ 90 ]. The proposed antenna is implemented on a FR-4 substrate with ε r = 4.7 and tan δ = 0.025 with a size of 30.5 mm × 21.02 mm × 6.4 mm, as shown in Figure 9 . The antenna performance is evaluated through simulation in a multi-layer human body model.
Compact meander line planar implantable antenna for a pacemaker [ 90 ]. Reproduced with permission from an open-access article from the Indonesian Journal of Electrical Engineering and Computer Science (CC-BY).
Figure 10 shows a tiny and compact implantable planar antenna with the size of 3 mm × 3 mm × 0.5 mm as presented in Ref. [ 25 ] for a wireless cardiac pacemaker. Rogers 3010 is used as a superstrate and substrate where ε r = 10.2 and tan δ = 0.0023. The antenna is optimized and loaded with a defective slotted structure to improve the efficiency and overall performance of the antenna in an ISM frequency band of 2.4 to 2.48 GHz. The definite bandwidth of the antenna is 22%, with the peak gain of −24.9 dBi.
Tiny and compact implantable planar antenna for a wireless cardiac pacemaker [ 25 ]. Reproduced with permission from an open-access article from Scientific Reports (CC-BY).
A triband spiral shaped implantable antenna is presented by Shah et al. in Ref. [ 68 ] with slotted ground operating at 402 MHz, 1.6 GHz and 2.45 GHz for a leadless pacemaker system. The size of the antenna is 7 mm × 6.5 mm × 0.377 mm, where Rogers RT/Duroid 6010 with ε r = 10.2 and tan δ = 0.0035 is utilized as a superstrate and substrate, as shown in Figure 11 . The gains of the antenna at the three different frequencies are −30.5 dBi, −22.6 dBi, −18.2 dBi, respectively, with bandwidths of 36.8%, 10.8% and 3.4%, respectively.
Triband spiral shaped antenna and its test setup in minced pork [ 68 ]. Copyright © IEEE .
The frequent rise and drop in blood pressure can originate a stroke or severe cardiovascular disease for patients, which necessitates the requirement for an accurate blood pressure monitoring system in a healthcare space.
The measurement of blood pressure through an implantable antenna system embedded into the heart would be an outstanding solution for risky heart patients. In Ref. [ 23 ], a pseudo-normal-mode helical antenna is presented with a poly-siloxane (PDMS) insulation layer, as shown in Figure 12 . The operation frequency of the antenna is 863–870 MHz with a size of 3 mm in diameter and 9.44 mm in height. The antenna is built with a 0.33 mm diameter nitinol wire. The implant antenna and sensor are put inside the left ventricle and subjected to experimentation with a pig, as shown in Figure 8 . This antenna can provide a maximum radiation efficiency of −27 dB and directivity of 2.65 dBi.
Helical wire antenna for blood pressure monitoring implant [ 23 ]. Reproduced with permission from an open-access article from Biomedical Microdevices (CC-BY).
A smart stent antenna is presented in Ref. [ 91 ] for intravascular monitoring, as shown in Figure 13 . The commonly used L-605 Cobalt–Chromium (Co–Cr) alloy is used as the material for the stent. The diameter and length of the stent are 2 mm and 18 mm, respectively. This antenna can achieve a gain of 1.38 dBi and a radiation efficiency of 74.5% at a resonant frequency of 2.07 GHz.
Smart stent antenna for intravascular monitoring [ 91 ]. Reproduced with permission from an open-access article from MDPI Sensors (CC-BY).
Figure 14 shows a miniaturized planar implantable antenna presented in Ref. [ 92 ] with an operation frequency of 2.4 GHz. The approximate size of the antenna is 10 mm × 10 mm × 1.5 mm, and it is manufactured with Taconic RF-35 with ε r = 3.5 and tan δ = 0.0018. The achieved bandwidth of the antenna is 14.9%, with the peak gain of −20.75 dBi.
Miniaturized planar implantable antenna for a brain implant [ 92 ]. Reproduced with permission from an open-access article from IEEE Access (CC-BY).
In Ref. [ 93 ], a 2.4 or 4.8 GHz planar implantable antenna with modified E-shape is presented, built with a Rogers TMM13i substrate with ε r = 12.2 and tan δ = 0.0019. The size of the implantable antenna is 10 mm × 8.7 mm × 0.76 mm. The maximum SAR achieved is 69 mW/Kg for 10 g of tissue.
The antenna presented in Ref. [ 68 ] is also compatible with a pacemaker application for a brain implant.
A novel flexible moon-shaped slot implantable antenna operating at 2.45 GHz frequency is presented for neural recording systems and brain implants in Ref. [ 94 ]. The size of the antenna is 8 mm × 9 mm × 0.2 mm, fabricated with a RO4003C substrate with ε r = 3.48 and tan δ = 0.0027. The peak gain achieved is approximately −13 dBi at 2.45 GHz. The maximum SAR achieved is less than 1 W/kg for 1 g of tissue.
Figure 15 shows a miniaturized planar implantable antenna proposed by Shah et al. for intracranial pressure monitoring at 915 MHz and 2.45 GHz [ 95 ]. The proposed antenna has a size of 8 mm × 6 mm × 0.5 mm and utilizes Rogers 6010 as the substrate with ε r = 10.2 and tan δ = 0.0023. Biocompatibility is confirmed by the ceramic alumina encapsulation. The antenna achieved a gain and bandwidth of −28.5 dBi and 9.84% at 915 MHz, respectively, and −22.8 dBi and 8.57% at 2.45 GHz, respectively. To achieve the safety limit of 2 W/kg for SAR 10g , the maximum allowable input power is 17.12 mW at 915 MHz and 20.6 mW at 2.45 GHz.
Miniaturized planar implantable antenna for intracranial pressure [ 95 ]. Copyright © IEEE .
A coplanar miniature antenna with the size of 6 mm × 5 mm × 1 mm is presented in Ref. [ 96 ] with an operation frequency of 2.45 GHz, as shown in Figure 16 . Khan et al. claimed to use low-permittivity polyimide as a flexible substrate for the proposed antenna. This antenna can provide a peak gain of −19.63 dBi and maximum SAR of 10 mW/kg in brain tissue.
Coplanar miniature antenna for intracranial pressure tested in liquid phantom [ 96 ]. Reproduced with permission from an open-access article from the International Journal of Antennas and Propagation (CC-BY).
In Ref. [ 97 ], a PIFA antenna design technique was explained for head-implanted medical devices, including intracranial pressure application. In this work, Rogers RO 3210 is selected as the substrate with ε r = 10.2 and tan δ = 0.003. The antenna is 12 mm in diameter and 1.8 mm in width. It was designed to operate at 402, 433, 868 and 915 MHz. It can achieve a SAR of 2 W/kg for 10 g of tissue when the input power is 4.927 mW. It can achieve a peak gain of −36.90, −35.99, −35.14 and −32.94 dB at 402, 433, 868 and 915 MHz, respectively.
A wireless power receiver spiral antenna with dimensions of 12.88 mm × 13.46 mm × 0.05 mm is presented by Waqas et al. in Ref. [ 98 ] for an intracranial pressure implant. The antenna is made on a flexible polyimide substrate with ε r = 3.3 and tan δ = 0.002. The operating frequency of the antenna was selected as 11 MHz, where a −2.17 dB measurement peak gain was achieved. The wireless power transfer efficiency was 1.18%.
In Ref. [ 99 ], a miniaturized single-fed wide-beamwidth circularly polarized implantable antenna working in the ISM band (2.40–2.48 GHz) is presented for subcutaneous real-time glucose level monitoring application. Figure 17 shows the proposed antenna with the dimensions of 8.5 mm × 8.5 mm × 1.27 mm employing four C-shaped slots and a complementary split-ring resonator (CSRR). Meanwhile, by adjusting the slits of the CSRR, circular polarization is realized. In this work, Rogers 3210 is selected as the substrate with ε r = 10.2 and tan δ = 0.003. The simulation results with a three-layer phantom demonstrate that the impedance bandwidth is 12.2%, with a peak gain of −17 dBi.
Proposed wide-beamwidth circularly polarized implantable antenna for glucose monitoring presented in Ref. [ 99 ]. Copyright © IEEE .
Mujeeb-U-Rahman et al. in Ref. [ 100 ] presented a spiral antenna for wireless power and data telemetry for an injectable glucose sensing device. The size of the antenna is 3 mm × 0.6 mm. It is operating at the 900 MHz ISM band, with the peak power gain of less than −30 dB. The power transfer efficiency of the inductive link is 0.1%. The antenna is built on a silicon substrate through a photolithography process, as shown in Figure 18 .
Injectable glucose sensing device with spiral antenna [ 100 ]. Reproduced with permission from an open-access article from Scientific Reports (CC-BY).
A planar implantable antenna for monitoring infection in an orthopedic implant is presented in Ref. [ 101 ] for the 860 to 960 MHz RFID ultra-high frequency (UHF) band, as shown in Figure 19 . The size of the antenna is 14 mm × 6 mm × 3 mm. It is fabricated on a FR4 substrate and achieves a peak gain of −22 dBi.
Planar implantable antenna for an UHF RFID-based orthopedic implant [ 101 ]. Copyright © IEEE .
A folded loop antenna built with a metal wire with the size of 38 mm × 38 mm × 2.2 mm and a wire radius of 0.3 mm is presented in Ref. [ 102 ] for a cochlear implant, as shown in Figure 20 . The operating frequency of the proposed antenna is 2.45 GHz, with a bandwidth of 8.57%. It realizes a gain of −0.1 dBi.
Folded loop wire antenna for a cochlear implant [ 102 ]. Reproduced with permission from Attribution-NoDerivaties 4.0 International shared at CSEM archive.
A PIFA antenna with a MedRadio (401–406 MHz) band is presented by Orfeas and Nikita in Ref. [ 103 ] for a retinal implant. The antenna diameter is approximately 12 mm with a thickness of 1.8 mm in PEEK encapsulation. In this work, Rogers 3210 is selected as the substrate with ε r = 10.2 and tan δ = 0.003. This antenna achieves a peak gain of −36.82 dBi with a bandwidth of 3.4% in PEEK encapsulation. It can achieve a SAR of 2 W/kg for 10 g of tissue when the input power is 21 mW in PEEK encapsulation.
Capsule endoscopy (CE) is the most common ingestible device, which is used for diagnosis and monitoring of different gastrointestinal (GI) disorders. A wide range of in-body antennas used for CE application over the last few years are described below.
A planar meandering antenna fabricated on a 0.1 mm thick polyimide flexible substrate (with ε r = 3.5 and tan δ = 0.0027) with 0.035 mm copper thickness is presented in Ref. [ 104 ], as shown in Figure 21 . The proposed antenna has dimensions of 28 mm × 12 mm, working with an operation frequency of 433 MHz. The measured peak gain is −39 dBi.
Fabricated planar meandering antenna with SMA connection [ 104 ]. Reproduced with permission from an open-access article from IEEE Access (CC-BY).
In Ref. [ 105 ], a circularly polarized (CP) helical implantable antenna is proposed. The proposed antenna operates at 2.4 GHz frequency with a gain of −19.83 dBi and a bandwidth of 290 MHz. A perfect electric conductor (PEC) is used to build and simulate this antenna with a 6.6 mm diameter and 8.85 mm length, with an approximate wire thickness of 0.4 mm. Furthermore, the antenna covers the cylindrical shape of the capsule with a diameter of 7.06 mm and length of 25 mm.
A 3D wireless power transfer receiver coil of 8.9 mm in diameter and 4.8 mm in thickness is presented in Ref. [ 61 ], as shown in Figure 22 . The proposed 3D coil is built with a 0.2 mm copper wire. It achieves 0.7% power transfer efficiency (PTE) and a SAR of 66 mW/kg for 10 g of tissue at 1 MHz operation frequency.
Three-dimensional wireless power transfer receiver coil for capsule endoscopy tested in gel phantom [ 61 ]. Reproduced with permission from an open-access article from MDPI Micromachines (CC-BY).
A conformal antenna with a frequency of 402, 433, 915 and 2450 MHz is presented with an achieved gain of −32.5, −30.4, −17.9 and −19.0 dBi, respectively [ 106 ]. The proposed antenna is printed on a 0.17 mm thick flexible Kapton substrate with ε r = 3.5 and tan δ = 0.0027. It has a size of 12 mm × 6 mm. The bandwidth of the antenna is reported to be 2.95 and 3.33 GHz.
A similar conformal differentially fed antenna with an operation frequency of 915 MHz is presented in Ref. [ 107 ]. The proposed antenna has dimensions of 32 mm × 5.8 mm, as shown in Figure 23 , and it is printed on a flexible polyimide substrate (with ε r = 3.5 and tan δ = 0.008) of 0.15 mm in thickness. The antenna achieves a peak gain of −21 dBi and a bandwidth of 8.9% tested in the phantom under 50 mm depth.
Conformal differentially fed antenna built in a capsule [ 107 ]. Copyright © IEEE .
Figure 24 shows a slot line fed antenna with the size of 7 mm × 7 mm constructed on a silicon substrate of approximately 0.675 mm in thickness with ε r = 11.9, which is presented in Ref. [ 108 ]. The proposed antenna is operating at a 915 MHz frequency. It can achieve a peak gain of −35.5 dBi and a bandwidth of 300 MHz, as tested in colon phantom. Furthermore, it achieves a SAR of 8 mW/kg for 1 g of colon tissue.
Miniaturized slot line fed antenna for capsule endoscopy [ 108 ]. Reproduced with permission from an open-access article from IET Microwaves, Antennas & Propagation (CC-BY).
A wideband multiple-input–multiple-output (MIMO) compact antenna for ingestible capsules is presented in Ref. [ 109 ], as shown in Figure 25 . The size of the antenna is 5 mm × 4.2 mm × 0.12 mm, operating at a 2.45 GHz frequency. The proposed MIMO antenna is manufactured on a Rogers RO3010 substrate with ε r = 10.2 and tan δ = 0.0022. It maintains a peak gain of −20.6 dBi and a bandwidth of 25%. It can achieve a SAR of 2 W/kg for 10 g of tissue when the input power is 3.97 mW.
Fabricated MIMO antenna tested inside minced meat [ 109 ]. Reproduced with permission from an open-access article from Scientific Reports (CC-BY).
In Ref. [ 110 ], a sub-micrometer-sized injectable wire antenna is presented for the purpose of smart sensing, modulation, as well as energy harvesting to power in-cell nano-electronic computing. Figure 26 shows the proposed cell rover device, which can help understand the cell biology for different diagnostic and therapeutic applications. The receiver coil antenna is built with an American Wire Gauge (AWG) 47 wire, with a thickness of 0.0355 mm. The diameter and length of the coil are 2 mm and 1 mm, respectively. The proposed antenna operates at a 4.5 MHz frequency. It can achieve a PTE of 0.63% and a SAR of 0.0226 mW/kg for 10 g of tissue.
Cell rover with wire antenna inserted into the cell membrane [ 110 ]. Reproduced with permission from an open-access article from Nature Communications (CC-BY).
In Ref. [ 111 ], an injectable IBBD is presented for pharmacology and optogenetics applications, as shown in Figure 27 . Pharmacology and optogenetics are widely used in neuroscience research to study the central and peripheral nervous systems. This IBBD includes a spiral antenna of approximately 5 mm in diameter, operating at a 13.56 MHz frequency. The spiral antenna is fabricated on a flexible sheet of copper clad polyimide.
Wireless, battery-free, injectable microsystems for programmable pharmacology and optogenetics applications [ 111 ]. Reproduced with permission from an open-access article from PNAS-Biological Sciences (CC-BY).
Table 1 , Table 2 and Table 3 summarize the different types of in-body antennas for implantable, ingestible and injectable IBBD applications, respectively, discussed in this section, highlighting their structure (type and substrate) and key performance parameters (size, gain, −10 dB bandwidth and SAR).
Summary of different types of in-body antennas used in implantable IBBD applications.
Antenna | Ref, Application | Frequency | Size (mm × mm × mm) | Substrate/Material | Gain (dBi) | Bandwidth | SAR mW/kg |
---|---|---|---|---|---|---|---|
Planar | [ ], Pacemaker | 402.5 MHz | 30.5 × 21.02 × 6.4 | FR-4, = 4.7, tan = 0.025 | - | 33.5% | - |
[ ], Pacemaker | 2.4 to 2.48 GHz | 3 × 3 × 0.5 | Rogers 3010, = 10.2, tan = 0.0023 | −24.9 | 22% | 147.7 | |
[ ], Brain implant | 2.4 GHz | 10 × 10 × 1.5 | Taconic RF-35, = 3.5, tan = 0.0018 | −20.75 | 14.9% | 0.3 | |
[ ], Brain implant | 2.4/4.8 GHz | 10 × 8.7 × 0.76 | Rogers TMM13i, = 12.2, tan = 0.0019 | - | 69 | ||
[ ], Intracranial pressure | 915 MHz, 2.45 GHz | 8 × 6 × 0.5 | Rogers 6010, = 10.2, tan = 0.0023 | −28.5, −22.8 | 9.84%, 8.57% | 2000 | |
[ ], Intracranial pressure | 2.45 GHz | 6 × 5 × 1 | Polymide | −19.63 | - | 10 | |
[ ], Orthopedic | 860 to 960 MHz | 14 × 6 × 3 | FR4 | −22 | - | - | |
PIFA | [ ], Intracranial pressure | 402, 433, 868 and 915 MHz | Dia = 12 mm, Thick = 1.8 mm | Rogers RO 3210, = 10.2, tan = 0.003 | −36.90, −35.99, −35.14 and −32.94 dB | - | 2000 |
[ ], Retinal implant | 401–406 MHz | Dia = 12 mm, Thick = 1.8 mm | Rogers RO 3210, = 10.2, tan = 0.003 | −36.82 | 3.4% | 2000 | |
Wire | [ ], Blood pressure monitoring | 863 to 870 MHz | Dia = 3 mm Length = 9.44 mm | Nilton wire, 0.33 mm thick | Directivity = 2.65 dBi | - | - |
[ ], Intravascular monitoring | 2.07 GHz | Dia = 2 mm, Length = 18 mm | Co–Cr alloy | −1.38 | - | - | |
[ ], Cochlear implant | 2.45 GHz | 38 × 38 × 2.2 | Metal wire, 0.3 mm thick | – 0.1 | 8.57% | - | |
Spiral | [ ], Brain implant and pacemaker | 402 MHz, 1.6 GHz and 2.45 GHz | 7 × 6.5 × 0.377 | Rogers RT/Duroid 6010, = 10.2, tan = 0.0035 | −30.5, −22.6, −18.2 | 36.8%, 10.8% and 3.4% | - |
[ ], Intracranial pressure | 11 MHz | 12.88 × 13.46 × 0.05 | Flexible polyimide, = 3.3, tan = 0.002 | –2.17 dB | - | - | |
Slot | [ ], Brain implant | 2.45 GHz | 8 × 9 × 0.2 | RO4003C, = 3.48, tan = 0.0027 | −13 | - | <1 W/kg for 1 g of tissue |
[ ], Glucose monitoring | 2.40 to 2.48 GHz | 8.5 × 8.5 × 1.27 | Rogers RO 3210, = 10.2, tan = 0.003 | −17 | 12.2% | - |
Summary of different types of in-body antennas used in ingestible IBBD applications.
Antenna | Ref, Application | Frequency | Size (mm × mm × mm) | Substrate/Material | Gain (dBi) | Bandwidth | SAR mW/kg |
---|---|---|---|---|---|---|---|
Planar | [ ], CE | 433 MHz | 28 × 12 × 0.035 | Polyimide, = 3.5, tan = 0.0027 | −39 dBi | - | - |
Wire | [ ], CE | 2.4 GHz | Dia = 6.6 mm, Length = 8.85 mm | PEC wire, 0.4 mm thick | −19.83 | 12% | |
[ ], CE | 1 MHz | Dia = 8.9 mm, Thick = 4.8 mm | Copper wire, 0.2 mm thick | 0.7% PTE | - | 66 | |
Conformal | [ ], CE | 402 MHz, 433 MHz, 915 MHz and 2.45 GHz | 12 × 6 × 0.17 | Kapton substrate, = 3.5, tan = 0.0027 | −32.5, −30.4, −17.9 and −19.0 | - | - |
[ ], CE | 915 MHz | 32 × 5.8 × 0.15 | Polyimide, = 3.5, tan = 0.008 | −21 | 8.9% | ||
Slot | [ ], CE | 915 MHz | 7 × 7 × 0.675 | Silicon substrate, = 11.9 | −35.5 dBi | 32.8% | 8 mW/kg for 1 g of tissue |
MIMO | [ ], CE | 2.45 GHz | 5 × 4.2 × 0.12 | Rogers RO 3010, = 10.2, tan = 0.0022 | −20.6 | 25% | 2000 |
Summary of different types of in-body antennas used in injectable IBBD applications.
Antenna | Ref, Application | Frequency | Size (mm × mm × mm) | Substrate/Material | Gain (dBi) | Bandwidth | SAR mW/kg |
---|---|---|---|---|---|---|---|
Spiral | [ ], Glucose sensing | 900 MHz | 3 × 0.6 | Silicon substrate (Photolithography process) | −30 dB | - | - |
[ ], Pharmacology and optogenetics | 13.56 MHz | Dia = 5 mm | Polyimide | - | - | - | |
Wire | [ ], Cell rover | 4.5 MHz | 2 × 1 | AWG 47 (0.0355 mm) | - | 0.63% | 0.0226 |
This section describes some of the limitations of the current in-body antenna designs and future challenges, which need to be resolved to improve performance.
A comprehensive review is presented for in-body antennas for IBBDs (implantables, ingestibles, injectables). Designing an in-body antenna operating in a harsh bio-tissue environment is a challenging task, where several specifications are required to be considered, including the operation frequency, band selection, size, performance (gain, efficiency, radiation pattern), biocompatibility and patient safety. Widely used miniaturization techniques, such as high-permittivity substrates, lengthier current flow path on the radiator, inductive or capacitive loading, pin shorting, higher operating frequencies, ground plane modifications and use of metamaterials, are discussed, and each technique is evaluated in terms of its merits and issues. This study shows that despite having the superior potential of miniaturization, higher frequency usage suffers from significant losses, which requires additional investigations in this domain, as radio wave exposure studies and research works at these frequencies are not yet well established. Moreover, this paper reviews the antenna design and manufacturing process and illustrates the antenna testing procedures, including in vitro and in vivo testing. This paper also summarizes several existing in-body antenna designs, including planar, PIFA, wire, conformal, spiral, slotted and MIMO structures, and classifies antennas according to the IBBD applications. Although the selection of an antenna type depends on specific applications, patch-type planar structures have been more commonly adapted by researchers, as shown in Table 1 . The study of patient safety is one of the primary requirements for IBBDs, which is strictly administered through the SAR and EIRP limits. Table 1 shows that most researchers ignore this step while designing in-body antennas for IBBDs, which is alarming, as it fails to demonstrate the suitability of the proposed antennas for in-body applications. In-body antennas are obligated to meet these regulations while considering the bio-tissue environment as the key testing platform and further confirming the safety profile through utilization of biocompatible materials. Finally, the article concludes with listing some of the drawbacks and limitations of existing in-body antenna technology and the forthcoming research challenges in this area.
This research is funded by Heriot-Watt University Kickstart Research fund granted to Sadeque Reza Khan.
Conceptualization, I.N. and S.R.K.; methodology, S.R.K.; software, I.N. and S.R.K.; validation, K.A. and I.N.; resources, K.A. and S.R.K.; writing—original draft preparation, S.R.K.; writing—review and editing, K.A., I.N. and S.R.K.; supervision, S.R.K.; funding acquisition, K.A. and S.R.K. All authors have read and agreed to the published version of the manuscript.
Conflicts of interest.
The authors declare no conflict of interest.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
IMAGES
VIDEO
COMMENTS
In this thesis, computational tools are investigated to augment the area of antenna analysis and design procedures. One of the primary techniques is the computation of physical limitations for antennas, which answers the question \how close is the performance of the antenna under design to the theoretical optimum."
The goal of this thesis is to design and analysis the Microstrip Patch Antenna which covers the Ultra Wide Band 3.1 to 10.6 GHz. This thesis covers study of basics and fundamentals of ... design antennas are fabricated on an inexpensive dielectric substrate FR-4 with relative permittivity (εr) of 4.4 with thickness of 1.6 mm. The simulation ...
It is important to design millimeter wave antennas with high gain characteristics due to their high sensitivity towards atmospheric absorption losses. ... In this thesis, planar antennas are designed using substrate integrated waveguide (SIW) technology to have low losses, high quality factor, and low fabrication cost. Firstly, an
A Degree Thesis Submitted to the Faculty of the Escola Tècnica d'Enginyeria de Telecomunicació de Barcelona Universitat Politècnica de Catalunya by ... For design an antenna I was using the FEKO software, FEKO is an electromagnetic simulation software tool for the electromagnetic field analysis of 3D structures. Which
In this thesis; a compact rectangular patch antennas are designed and tested for GPS devices at 1.57542 GHz, and for a satellite TV signal at 11.843 GHz and 11.919 GHz. The final part of this work has been concentrated on studying an array antenna with two and four elements. The antennas of the design examples
resistance can be calculated. The power radiated is expressed in Equation 2.4, which is done by. integrating the real part of the complex Poytning vector over a surface located in the far-field. 2 = 1 ∫∫⃗⃗×⃗⃗⃗∗. (2.4) The power delivered to an antenna is the sum of the radiated power plus power dissipated.
In this thesis, the design methods and synthesis procedures are detailed in order to deliver a comprehensive guide of designing the dual polarized antenna arrays. The design concept and outcomes of these antenna arrays are evaluated in the high frequency full-wave solver. All of the antenna arrays are prototyped and measured for validating the
The 4x4 subarray antenna was designed with an interelement spacing of 0.8λ and was solved for individual element patterns using a full wave solver before applying postprocessing on it. The ...
Novel Approaches to the Design of Phased Array Antennas By Danial Ehyaie A dissertation submitted in partial fulfillment of the requirement for the degree of
This thesis focuses on the design and optimization of antennas specifically tailored for sub-6GHz 5G applications, aiming to enhance coverage and capacity in 5G wireless networks. ... In the second antenna design, we further extended our work on designing a compact dual-element MIMO antenna with dual-band characteristics for GSM-900 (0.88-1.08 ...
A 50-microstrip line with length of Sel that connect to the coplanar waveguide (CPW) as shown in Figure 3. The length LMS is used to transform the quasi-TEM of the microstrip line into the TE of the SIW antenna. The transition design is easy to achieve, and the quality factor. (Q) is largely that effect by the distance LMS and the trace width WM2.
A conventional wideband log periodic microstrip antenna without slot and ring is designed, which covers the wideband of almost 1.7-4.1GHz. Optimization of the same conventional design has been done by making a slot of 1cm×0.5cm at end of arm and 0.1cm ring at the outer side which covers the band of 1.04-4.9 GHz.
In this thesis, the microstrip patch antennas from narrowband to ultra-wideband are designed and implemented to use in IBFD operation. The implemented 2.4 GHz and 5.8 GHz IBFD differential fed microstrip patch antenna arrays and 2.4 GHz IBFD double ... Figure 3.5: Three port two elements microstrip patch antenna array (a) HFSS design (b)
Figure 2. Typical UWB MIMO antenna design approaches. A four-element compact MIMO antenna with a total volume of 26 × 26 × 0.8 mm 3 and a 4 mm edge-to-edge distance between the radiating patches is reported in [ 21 ]. A groove is carved in the center of the GP ( Figure 3) to prevent mutual coupling.
This thesis presents the design of two circularly polarized patch antennas for operation at 1.767 GHz and at 2.207 GHz (for receiving and transmitting, respectively) on NPSAT1 satellite. The design requirements for the antennas include a VSWR of less than or equal to 2:1 for 50 Ω reference impedance. The study includes of the
This thesis investigates several antenna applications of artificial magnetic materials (AMMs). The initial work is devoted to the design of a spiral resonator (SR) AMM slab ... the antenna design strategies have become more complex. On the other hand, over the last decades, Metamaterials (MTMs) have caught the ...
This thesis begins with the theory of channel capacity in the communication channel links. The need of large channel capacity and high data rate are motivated to design, develop, and implement MIMO antenna whereas can be utilized in the transmitter and/or receiver of the user devices. This is possible by finding the suitable antenna structures ...
The goal of this thesis is to design and analysis the Microstrip Patch Antenna which covers the Ultra Wide Band 3.1 to 10.6 GHz. This thesis covers study of basics and fundamentals of microstrip patch antenna. A series of parametric study were done to find that how the characteristics of the antenna depends on its various geometrical and other parameters.
DEPARTMENT OF ELECTRICAL ENGINEERING NATIONAL INSTITUTE OF TECHNOLOGY, ROURKELA ODISHA, INDIA-769008 CERTIFICATE This is to certify that the thesis entitled "Design of ultra small microstrip patch antenna for wireless communication applications", submitted by Tanya Sharma (109EE0615) and Oshin Atal (109EE0530) in partial fulfilment of the requirements for the award of Bachelor
This paper describes the trends that are being followed in 5G antenna design. The antenna design techniques that are used in Sub-6 GHz range to achieve better isolation, efficiency and channel capacity will be discussed. Increasing the number of antenna in 5G MIMO antenna array can increase the efficiency up to 80% and capacity more than 50b/s/Hz in sub-6GHz range. Apart from this, designs of ...
antennas. This thesis shows the design, characterisation, simulation and measurements of four different antennas to work at ISM band and seventeen different scenarios for body wireless communication. A 3- layer (skin, fat and muscle) and a . iv
MS Thesis Antenna Design - Free download as PDF File (.pdf), Text File (.txt) or read online for free. This is Masters Level Thesis which describes the design and fabrication of Koch fractal Antenna
This review work aims to describe the design specifications, implementation and testing techniques, challenges and different applications of in-body antennas. Following the Introduction, the paper is divided into six sections. Section 2 briefly highlights the design specifications of in-body antennas.